Fluke 117 Multimeter
$67.26
$81.38
Fluke 117 Multimeter The Fluke 117 Multimeter is perfect for use in the field for any electrical measurements you may need to take. It features Fluke’s VoltAlert™ which allows for non-contact voltage detection. The Fluke 117 will also automatically select either AC/DC voltage. It also has a feature which allows you to see the Min/Max/Average with the elapsed time. The Fuke 117 is CAT III 600 V safety rated. It has a compact design that allows you to easily use it with one hand. It is capable of measuring up to 10A along with voltage, resistance, continuity, frequency, and capacitance. Specifications Maximum voltage between any terminal and earth ground 600 V Surge protection 6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2 Fuse for A input 11 A, 1000 V FAST Fuse (Fluke PN 803293) Display Digital: 6,000 counts, updates 4 per second Bar graph 33 segments, updates 32 per second Operating temperature -10°C to 50°C Storage temperature -40°C to 60°C Battery type 9 volt Alkaline, NEDA 1604A / IEC 6LR61 Battery life 400 hours typical, without backlight Accuracy Specifications DC millivolts Range/resolution 600.0 mV / 0.1 mV Accuracy ±([% of reading] [counts]): 0.5% 2 DC volts Range/resolution 6.000 V / 0.001 V 60.00 V / 0.01 V 600.00 V / 0.1 V Accuracy ±([% of reading] [counts]): 0.5% 2 Auto volts Range/resolution 600.0 V / 0.1 V Accuracy 2.0% 3 (DC, 45 Hz to 500 Hz) 4.0% 3 (500 Hz to 1 kHz) AC millivolts¹ True RMS Range/resolution 600.0 mV / 0.1 mV Accuracy 1.0% 3 (DC, 45 Hz to 500 Hz) 2.0% 3 (500 Hz to 1 kHz) AC volts¹ True RMS Range/resolution 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V Accuracy 1.0% 3 (DC, 45 Hz to 500 Hz) 2.0% 3 (500 Hz to 1 kHz) Continuity Range/resolution 600 Ω / 1 Ω Accuracy Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer. Ohms Range/resolution 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ Accuracy 0.9% 1 Range/resolution 40.00 MΩ / 0.01 MΩ Accuracy 5% 2 Diode test Range/resolution 2.00 V / 0.001 V Accuracy 0.9% 2 Capacitance Range/resolution 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF Accuracy 1.9% 2 Range/resolution > 1000 μF Accuracy 5% 20% Lo-Z capacitance Range 1 nF to 500 μF Accuracy 10% 2 typical AC amps True RMS (45 Hz to 500 Hz) Range/resolution 6.000 A / 0.001 A 10.00 A / 0.01 A Accuracy 1.5% 3 20 A continuous overload for 30 seconds max DC amps Range/resolution 6.000 A / 0.001 A 10.00 A / 0.01 A Accuracy 1.0% 3 20 A continuous overload for 30 seconds max Hz (V or A input)² Range/resolution 99.99 Hz / 0.01 Hz 999.99 Hz / 0.1 Hz 9.999 Hz / 0.001 Hz 50.00 Hz / 0.01 Hz Accuracy 0.1% 2
Cathodic Protection